Main characteristics of Injecta Hydra HYPR5LNPFFC00 (with pH/ORP sensor input)
Digital Dosing pump with flow rate manual adjustment and proportional dosing based on the measurement of pH or ORP value.
Temperature compensation.
Temperature sensor PT100 (on request)
Input ON-OFF (remote control)
PVDF-C pump head
Double ceramic balls
Pure PTFE diaphragm for full compatibility with all chemicals.
Flow rate manual adjustment between 0-100%
Manual priming valve
Wall mounting with fixing bracket
Anti-seepage system
Anti-seepage system is an ability of Injecta Hydra HYPR5LNPFFC00 (with pH/ORP sensor input)
The anti-seepage system, is a solution to prevent the intrusion of chemical
product inside the pump: leakage and chemical intrusion can happen when the O-
ring is damaged or consumed by regular use.
This device is integrated in the hydraulic part, between pump head and body,
behind the diaphragm: the outgoing collection channel of the anti-seepage
device (see below blue arrow) collects the leakage and expel it out.
When the leakage is visible, the operator can proceed either tightening the 4 bolts
of the head (4Nm torque) or disassembling the head and inspect it in order to
understand leakage causes .